Wilde Analysis Ltd.

Wilde Analysis Ltd.

Whitworth House, Stockport SK1 3JR, United Kingdom

Wind Microclimate Assessment

Wind Microclimate Assessment

CFD is becoming an increasingly popular alternative or complement to wind tunnel testing when assessing the environment adjacent to buildings and its impact on pedestrian comfort. We have developed efficient methodologies for evaluating the suitability of building developments against standard criteria and offer both technology transfer and project services.

Planning applications for large buildings in the urban environment often require wind microclimate assessment. Traditionally, this has been undertaken with wind tunnel testing of a scale model but simulation has now become established as a practical option.

By early involvement in a project while building massing is still flexible, we can help to engineer out problem wind flows and avoid expensive last minute delays in the planning process.

We work closely with architects, developers, councils, civil & structural engineers and planning consultants to understand wind flows around new developments. This includes terrain analysis and study of meteorological data, using CFD for early identification of potential issues with pedestrian safety & comfort and the evaluation of any necessary wind mitigation measures.

Through a pragmatic yet effective approach, we are able to deliver results efficiently and accurately compared to alternative assessment methods.

Example of Streamlines from a Wind Flow Analysis (Courtesy: WSP)

In addition to consulting services, we help companies involved in wind engineering develop their own capability through the supply of ANSYS CFD software and training.

wind-microclimate-lq-bream-street
Past project at Bream Street, Fish Island (Courtesy: L&Q)

Example projects include:

Student Residence at the Bishop Gate Site, Coventry (Barberry)
Bream Street Development on Fish Island, London (L&Q Group)
City block (WSP Environment & Energy)

Example of a Wake Flow Profile (Courtesy: WSP)

By modelling wind flows, we can also investigate the effect of pressure loading on structures, through 1-way or 2-way fluid-structure interaction (FSI) capabilities.

Pressure contour map due to wind loading (Courtesy: Millwood House Consultants)

We are experienced in helping clients use structural analysis in conjunction with wind flow simulations to design in accordance to relevant codes such as BS EN 1991-1-4 and BS EN 1993-4-1.